Abstract
On the safety level of pile design using the finite element method. As part of the ongoing revision of Eurocode 7 (EC 7), the design of geotechnical structures using numerical methods is being regulated in a normative manner for the first time. The procedure proposed in the revised EC 7 includes the Input Factoring Approach (IFA) and the Output Factoring Approach (OFA). It is generally assumed that the IFA is primarily intended for the verification of ground failure, whereas the OFA is mainly applicable to structural member verifications. With the introduction of this alternative verification concept, it is essential to ensure that the established safety level is not significantly altered. This requirement necessitates appropriate comparative studies. In this paper, such comparative studies are presented using the example of the verification of the external bearing capacity of a vertically loaded single pile. Both end-bearing piles and friction piles are investigated. The results indicate that, in this case, verification according to the IFA concept consistently provides a safety level that lies within the range of the safety factors commonly applied to date. It can therefore be concluded that a numerical verification of the external bearing capacity of axially loaded piles using the procedures proposed in EC 7 is appropriate and may be considered a viable alternative design approach in future practice.
| Original language | German |
|---|---|
| Number of pages | 7 |
| Journal | Bautechnik |
| Early online date | 30 Jun 2026 |
| DOIs | |
| Publication status | E-pub ahead of print - 30 Jun 2026 |