N2 - In this paper geometric and radiometric investigations performed with two Leica/Helava DSW200 scanners will be presented. Good quality test patterns and accurate processing methods for their performance evaluation have been employed. The geometric tests include global and local geometric errors, misregistration between colour channels, geometric repeatability, and determination of the geometric resolution. Efforts were made to separate the contribution of various error sources (especially mechanical positioning, electronic errors and lens distortion) on the total error. The radiometric tests include investigations on noise, linearity, dynamic range, spatial, temporal and spectral variation of noise, and artifacts. After a brief description of the scanner, details on the above investigations, used analysis methods and achieved results will be presented. The most important errors, especially for organisations employing the scanner in production, are nonrepeatable geometric errors that are due to mechanical positioning inaccuracies and vibrations. This causes whole CCD image tiles (4 million pixels) to be systematically shifted with respect to their neighbouring tiles, with obvious negative influence on any subsequent measuring task.
AB - In this paper geometric and radiometric investigations performed with two Leica/Helava DSW200 scanners will be presented. Good quality test patterns and accurate processing methods for their performance evaluation have been employed. The geometric tests include global and local geometric errors, misregistration between colour channels, geometric repeatability, and determination of the geometric resolution. Efforts were made to separate the contribution of various error sources (especially mechanical positioning, electronic errors and lens distortion) on the total error. The radiometric tests include investigations on noise, linearity, dynamic range, spatial, temporal and spectral variation of noise, and artifacts. After a brief description of the scanner, details on the above investigations, used analysis methods and achieved results will be presented. The most important errors, especially for organisations employing the scanner in production, are nonrepeatable geometric errors that are due to mechanical positioning inaccuracies and vibrations. This causes whole CCD image tiles (4 million pixels) to be systematically shifted with respect to their neighbouring tiles, with obvious negative influence on any subsequent measuring task.
KW - CCD
KW - Colour misregistration
KW - Film scanner
KW - Geometric evaluation
KW - Radiometric evaluation
KW - Scanner test
UR - https://www.scopus.com/pages/publications/0345207565
U2 - 10.1117/12.279777
DO - 10.1117/12.279777
M3 - Conference Paper
AN - SCOPUS:0345207565
VL - 3174
T3 - Proceedings of SPIE - The International Society for Optical Engineering
SP - 157
EP - 173
BT - Proceedings of SPIE - The International Society for Optical Engineering
T2 - Videometrics V
Y2 - 30 July 1997 through 30 July 1997
ER -