Bemessungshilfen für die Heißbemessung ungeschützter Stahlprofile auf Basis des Eurocode 3 Teil 1-2

Translated title of the contribution: Design tables for the fire design of unprotected steel sections due to Eurocode 3 part 1-2

Manuel Krahwinkel, Tobias Petersen, Christian Gehmert

Abstract

Fire design for unprotected steel sections is based on Eurocode 3 part 1-2 using reduction factors for material properties at elevated temperatures. To calculate the steel tem perature during a fire Eurocode 3 part 1-2 gives a time-increment-method which is not suitable for hand calculations. For this reason this paper presents design tables with steel temperatures of steel sections subjected to a fire resistance class R30 respectably 30 min of a standard fire. Additional design tables are presented for the fire design of steel members subjected to buckling and lateral torsional buckling. The use of the design tables is illustrated by worked examples.
Translated title of the contributionDesign tables for the fire design of unprotected steel sections due to Eurocode 3 part 1-2
Original languageGerman
Pages (from-to)840–849
JournalStahlbau
Volume81
Issue number11
DOIs
Publication statusPublished - Nov 2012

Keywords

  • calculation of steel temperature
  • elevated temperature
  • steel section
  • design table
  • Analysis and calculation
  • Fire protection
  • Steel buildings

Cite this